Published 1987 | Version public
Book Section - Chapter Open

Unsteady Diffuser Vane Pressure and Impeller Wake Measurements in a Centrifugal Pump

Abstract

Unsteady surface pressure measurements on a vaned diffuser of a centrifugal pump, and wake measurement of the flow exiting a centrifugal impeller into a vaneless diffuser are presented. Frequency spectra and ensemble averages are given for the unsteady measurements. Two different impellers were used, the pump impeller of the HPOTP (High Pressure Oxygen Turbopump) of the SSME (Space Shuttle Main Engine) and a two-dimensional impeller. The magnitude of the unsteady total pressure measured in the stationary frame at the impeller exit was found to be of the same order of magnitude as the total pressure rise across the pump. The magnitude of the unsteady diffuser vane pressures was observed to be significantly different on suction and pressure side of the vane, attaining its largest value on the suction side near the leading edge while decreasing along the vane.

Additional Information

The authors are indebted to the NASA George Marshall Space Flight Center for continued sponsorship of this research under contract NAS8-33108.