Published October 16, 2012 | Version Published + Supplemental Material
Journal Article Open

Cognitive Signals for Brain-Machine Interfaces in Posterior Parietal Cortex Include Continuous 3D Trajectory Commands

  • 1. ROR icon California Institute of Technology
  • 2. ROR icon Massachusetts Institute of Technology
  • 3. ROR icon Huntington Hospital
  • 4. ROR icon University of Southern California

Abstract

Cortical neural prosthetics extract command signals from the brain with the goal to restore function in paralyzed or amputated patients. Continuous control signals can be extracted from the motor cortical areas, whereas neural activity from posterior parietal cortex (PPC) can be used to decode cognitive variables related to the goals of movement. Because typical activities of daily living comprise both continuous control tasks such as reaching, and tasks benefiting from discrete control such as typing on a keyboard, availability of both signals simultaneously would promise significant increases in performance and versatility. Here, we show that PPC can provide 3D hand trajectory information under natural conditions that would be encountered for prosthetic applications, thus allowing simultaneous extraction of continuous and discrete signals without requiring multisite surgical implants. We found that limb movements can be decoded robustly and with high accuracy from a small population of neural units under free gaze in a complex 3D point-to-point reaching task. Both animals' brain-control performance improved rapidly with practice, resulting in faster target acquisition and increasing accuracy. These findings disprove the notion that the motor cortical areas are the only candidate areas for continuous prosthetic command signals and, rather, suggests that PPC can provide equally useful trajectory signals in addition to discrete, cognitive variables. Hybrid use of continuous and discrete signals from PPC may enable a new generation of neural prostheses providing superior performance and additional flexibility in addressing individual patient needs.

Additional Information

© 2012 National Academy of Sciences. Freely available online through the PNAS open access option. Contributed by Richard A. Andersen, September 4, 2012 (sent for review June 23, 2012). Published online before print October 1, 2012. We thank I. Kagan for performing the MRI scans, K. Pejsa for animal care, and V. Shcherbatyuk and T. Yao for technical and administrative assistance. This work was supported by the Defense Advanced Research Projects Agency, the National Eye Institute of the National Institutes of Health, the Boswell Foundation and an Alfred E. Mann doctoral fellowship to M.H. Author contributions: M.H., G.H.M., G.E.L., and R.A.A. designed research; M.H. performed research; I.F. performed surgical procedures; M.H. analyzed data; and M.H., G.H.M., and R.A.A. wrote the paper. The authors declare no conflict of interest. This article contains supporting information online at www.pnas.org/lookup/suppl/doi:10.1073/pnas.1215092109/-/DCSupplemental.

Attached Files

Published - PNAS-2012-Hauschild-17075-80.pdf

Supplemental Material - pnas.201215092SI.pdf

Supplemental Material - sm01.avi

Supplemental Material - sm02.avi

Supplemental Material - sm03.avi

Files

PNAS-2012-Hauschild-17075-80.pdf

Files (21.1 MB)

Name Size
md5:4be2dd57eb3b509f1cd553ea9a1781c0
2.6 MB Preview Download
md5:05e286f1ac21f34b2a7e42b7f5967012
856.8 kB Preview Download
md5:a60335423b9f129bb7fa30a009900425
4.3 MB Download
md5:20ba936cb38c51d66caa5614894f4879
9.3 MB Download
md5:45cd9c766ac62d9ef3ef5f057e83663f
4.0 MB Download

Additional details

Identifiers

PMCID
PMC3479517
Eprint ID
35768
Resolver ID
CaltechAUTHORS:20121203-131000589

Funding

Defense Advanced Research Projects Agency (DARPA)
NIH
James G. Boswell Foundation
Alfred E. Mann doctoral fellowship

Dates

Created
2012-12-04
Created from EPrint's datestamp field
Updated
2023-10-20
Created from EPrint's last_modified field