Published March 2022 | Version public
Journal Article

Bony fixation in the era of spinal robotics: A systematic review and meta-analysis

  • 1. ROR icon University of California, Irvine
  • 2. ROR icon University of Southern California
  • 3. ROR icon California Institute of Technology
  • 4. ROR icon University of California, San Diego
  • 5. ROR icon Northwestern University
  • 6. ROR icon Case Western Reserve University
  • 7. ROR icon University of Arkansas for Medical Sciences

Abstract

Background. Accurate spinal screw placement in spinal instrumentation is of utmost importance to avoid injury to surrounding neurovascular structures. This study was performed to investigate differences in accuracy, operating room time, length of stay, and operative blood loss across studies involving all types of spinal fixation. Methods. PubMed, EMBASE, and Scopus were systematically queried to identify articles that fit the inclusion and exclusion criteria. Meta-analysis was performed using R software, and odds ratios and 95% CIs were calculated. Results. Sixty-nine articles were included in qualitative synthesis, and 35 studies in the meta-analysis, for a total of 8,174 robotically placed screws in 1,492 patients compared to 9,791 conventionally placed screws in 1,638 patients. A total of 9 screw trajectories were studied in the literature, although only 4 had enough evidence to be included in the meta-analysis. Robotic screw placement was more accurate than conventional screw placement (OR 2.24; 95% CI, 1.71–2.94). Robotic placement was not associated with significantly different postoperative length of stay (SMD −0.32; 95% CI, −1.20, 0.51), operative blood loss (SMD −0.25; 95% CI, −0.79, 0.19), or operative duration (SMD 0.08; 95% CI −1.00, 1.39). A total of 8 robotic platforms were found in the literature with accuracy rates above 93%. Conclusion. Robotic spinal fixation is associated with increased screw placement accuracy and similar operative blood loss, length of stay, and operative duration. These findings support the safety and cost-effectiveness of robotic spinal surgery across the spectrum of robotic systems and screw types.

Additional Information

© 2022 Elsevier. Received 2 October 2021, Accepted 8 January 2022, Available online 19 January 2022, Version of Record 19 January 2022. The authors declare that they have no known competing financial interests or personal relationships that could have appeared to influence the work reported in this paper.

Additional details

Identifiers

Eprint ID
114749
Resolver ID
CaltechAUTHORS:20220513-557980000

Dates

Created
2022-05-13
Created from EPrint's datestamp field
Updated
2022-05-13
Created from EPrint's last_modified field