Published June 6, 2022 | Version Published + Supplemental Material
Journal Article Open

Implementation of free-space Fourier Ptychography with near maximum system numerical aperture

  • 1. ROR icon California Institute of Technology

Abstract

Over the past decade, the research field of Fourier Ptychographic Microscopy (FPM) has seen numerous innovative developments that significantly expands its utility. Here, we report a high numerical aperture (NA) FPM implementation that incorporates some of these innovations to achieve a synthetic NA of 1.9 – close to the maximum possible synthetic NA of 2 for a free space FPM system. At this high synthetic NA, we experimentally found that it is vital to homogenize the illumination field in order to achieve the best resolution. Our FPM implementation has a full pitch resolution of 266 nm for 465 nm light, and depth of field of 3.6 µm. In comparison, a standard transmission microscope (incoherent) with close to maximum possible NA of 0.95 has a full pitch resolution of 318 nm for 465 nm light, and depth of field of 0.65 µm. While it is generally assumed that a free-space coherent imaging system and a free-space incoherent imaging system operating at their respective maximum NA should give comparable resolution, we experimentally find that an FPM system significantly outperforms its incoherent standard microscopy counterpart in resolution by a factor of 20%. Coupled with FPM's substantially longer effective depth of field (5.5 times longer), our work indicates that, in the near-maximum NA operation regime, the FPM has significant resolution and depth of field advantages over incoherent standard microscopy.

Additional Information

© 2022 Optica Publishing Group under the terms of the Optica Open Access Publishing Agreement. Received 4 Apr 2022; revised 6 May 2022; accepted 14 May 2022; published 23 May 2022. The LED quasi-dome used in this paper was generously donated by Laura Waller's research group from University of California, Berkeley. The authors thank Cheng Shen for helpful discussion about illumination correction methods and depth of field of high-NA FPM. Funding. Merkin Institute for Translational Research (13520291); National Institutes of Health (CA233363). Data availability. Data underlying the results presented in this paper are not publicly available at this time but may be obtained from the authors upon reasonable request. The authors declare no conflicts of interest.

Attached Files

Published - oe-30-12-20321.pdf

Supplemental Material - 5838619.pdf

Files

oe-30-12-20321.pdf

Files (8.4 MB)

Name Size
md5:f9649af4b12179fb9c649c7f350f0b72
3.4 MB Preview Download
md5:8e6ff56908dd7c2ff1797d33feb2d070
5.0 MB Preview Download

Additional details

Identifiers

PMCID
PMC9363023
Eprint ID
115762
Resolver ID
CaltechAUTHORS:20220722-768660000

Related works

Describes
10.1364/OE.459833 (DOI)

Funding

Caltech Merkin Institute for Translational Research
13520291
NIH
CA233363

Dates

Created
2022-07-25
Created from EPrint's datestamp field
Updated
2023-07-06
Created from EPrint's last_modified field

Caltech Custom Metadata