Bulk and Surface Charge Collection: CDMS Detector Performance and Design Implications

Abstract

The Cryogenic Dark Matter Search (CDMS) searches for Weakly Interacting Massive Particles (WIMPs) with cryogenic germanium particle detectors. These detectors discriminate between nuclear‐recoil candidate and electron‐recoil background events by collecting both phonon and ionization energy from interactions in the crystal. Incomplete ionization collection results in the largest background in the CDMS detectors as this causes electron‐recoil background interactions to appear as false candidate events. Two primary causes of incomplete ionization collection are suface and bulk charge trapping. Recent work has been focused on reducing surface trapping through the modification of fabrication methods for future detectors. Analyzing data taken with test devices shows that hydrogen passivation of the amorphous silicon blocking layer does not reduce the effects of surface trapping. Other data shows that the iron‐ion implantation used to lower the critical temperature of the tungsten transition‐edge sensors increases surface trapping, causing a degradation of the ionization collection. Using selective implantation on future detectors may improve ionization collection for events near the phonon side detector surface. Bulk trapping is minimized by neutralizing ionized lattice impurities. Detector investigations at testing facilities and at the experimental site in Soudan, MN have provided methods to optimize the neutralization process and monitor running conditions to maintain maximal ionization collection.

Additional Information

© 2009 American Institute of Physics. Published online 16 December 2009. This work is supported in part by the National Science Foundation (Grant Nos. AST-9978911, PHY-0542066, PHY-0503729, PHY-0503629, PHY-0503641, PHY-0504224, PHY-0705052, PHY-0801536, PHY-0801708, PHY-0801712 and PHY-0802575), by the Department of Energy (Contracts DE-AC03-76SF00098, DE-FG02-91ER40688, DE-FG02-92ER40701, DEFG03-90ER40569, and DE-FG03-91ER40618), by the Swiss National Foundation (SNF Grant No. 20-118119), and by NSERC Canada (Grant SAPIN 341314-07).

Attached Files

Published - 1.3292423.pdf

Files

1.3292423.pdf

Files (875.1 kB)

Name Size
md5:3d731f7a53e6d28c9982cced33379441
875.1 kB Preview Download

Additional details

Identifiers

Eprint ID
67007
Resolver ID
CaltechAUTHORS:20160511-143815913

Funding

NSF
AST-9978911
NSF
PHY-0542066
NSF
PHY-0503729
NSF
PHY-0503629
NSF
PHY-0503641
NSF
PHY-0504224
NSF
PHY-0705052
NSF
PHY-0801536
NSF
PHY-0801708
NSF
PHY-0801712
NSF
PHY-0802575
Department of Energy (DOE)
DE-AC03-76SF00098
Department of Energy (DOE)
DE-FG02-91ER40688
Department of Energy (DOE)
DE-FG02-92ER40701
Department of Energy (DOE)
DE-FG03-90ER40569
Department of Energy (DOE)
DE-FG03-91ER40618
Swiss National Science Foundation (SNSF)
20-118119
Natural Sciences and Engineering Research Council (Canada) (NSERC)
SAPIN 341314-07

Dates

Created
2016-05-12
Created from EPrint's datestamp field
Updated
2021-11-11
Created from EPrint's last_modified field

Caltech Custom Metadata

Series Name
AIP Conference Proceedings
Series Volume or Issue Number
1185