Incipient Cavitation in Axial Flow Pumps Part II Hydrodynamic Noise and Tip Vortex Cavitation
Creators
Abstract
The first occurrence of noise in an axial flow pump is correlated with the visually observed inception of cavitation for a range of tip clearances and flow rates. The magnitude of the sound level in the machine is determined as a function of the cavitation number for several tip clearances. However, the peak sound level does not depend much on tip clearances, and is about 35 db. above the ambient level.
Additional Information
Department of the Navy Naval Ordnance Test Station Contract N123s-91875 Task Order No. 6. Report No. E-56.2.Attached Files