Published October 20, 1993 | Version Published
Book Section - Chapter Open

Integration and evaluation of a near-infrared camera utilizing a HgCdTe NICMOS3 array for the Mt. Palomar 200-inch Observatory

Contributors

Abstract

In this paper we describe the main subsystems that constitute the Mt. Palomar Prime Focus InfraRed Camera (PFIRCAM), together with some of the characterization data obtained for the focal plane array. This camera is currently a facility instrument at the 200-inch Mt. Palomar Observatory. It helps to satisfy the observational needs of astronomers in the spectral range of 1 micrometers to 2.5 micrometers by utilizing a HgCdTe NICMOS3 array. The camera has a plate scale of 0.54 arcsec/pixel for an overall FOV of 138 X 138 arcsec.

Additional Information

© 1993 Society of Photo-Optical Instrumentation Engineers (SPIE). The research described in this paper was carried out by the Jet Propulsion Laboratory, California Institute of Technology, under a contract with the National Aeronautics and Space Administration. Reference herein to any specific commercial product, process, or service by trade name, trademark, manufacturer, or otherwise, does not constitute or imply its endorsement by the United States Government or the Jet Propulsion Laboratory, California Institute of Technology.

Attached Files

Published - 534.pdf

Files

534.pdf

Files (1.2 MB)

Name Size
md5:3119322e889306ef7494b64b340885e4
1.2 MB Preview Download

Additional details

Identifiers

Eprint ID
88462
Resolver ID
CaltechAUTHORS:20180801-133516970

Funding

NASA/JPL/Caltech

Dates

Created
2018-08-01
Created from EPrint's datestamp field
Updated
2021-11-16
Created from EPrint's last_modified field

Caltech Custom Metadata

Caltech groups
Infrared Processing and Analysis Center (IPAC) , Physics Department
Series Name
Proceedings of SPIE
Series Volume or Issue Number
1946